Sinaga, Muhammad Arif Ikhsan and Kurniati, Dwi (2023) EVALUASI KINERJA SEISMIK BANGUNAN GEDUNG DENGAN ANALISIS PUSHOVER MENGGUNAKAN BANTUAN PROGRAM ETABS EVALUATION OF SEISMIC PERFORMANCE OF BUILDINGS WITH PUSHOVER ANALYSIS USING ETABS PROGRAM ASSISTANCE. Tugas Akhir thesis, University Of Technology Yogyakarta.
|
Text
5170811327_M.Arif Ikhsan Sinaga_abstrak - done.pdf Download (59kB) |
Abstract
ABSTRAK Perkembangan pembangunan di dunia pendidikan kini semakin tinggi. Hal ini menuntut Universitas Alma Ata Yogyakarta (UAAY) untuk terus menciptakan dan membangun prasarana pendukung dan tempat yang memadai bagi mahasiswa dengan di wujudkan dalam pembangunan gedung AL-Musthofa. Tujuan dari penelitian ini adalah untuk mengetahui level kinerja struktur dari gedung Al-Mustofa Yogyakarta setelah dilakukan evaluasi kinerja struktur dengan metode Pushover berdasarkan ATC-40 dan nilai gaya geser dan gedung Al-Mustofa Yogyakarta setelah dilakukan evaluasi kinerja struktur menggunakan metode Pushover. Hasil pehitungan Performance Level ATC-40 dengan rasio 0,00591 untuk arah x dan 0,00535 untuk arah y, maka level kinerja struktur ini adalah Immediately Occupancy, yang berarti saat terjadi gempa maka bangunan ini tidak mengalami kerusakan.. Hasil analisis Pushover dengan menggunakan program Etabs maka diperoleh hasil kinerja struktur (Performance point) dengan gaya sebesar 12729,293 kN, dan Displacement maksimal sebesar 189,085 mm untuk arah x, serta 13240,379 kN dan Displacement maksimal sebesar 171,189 mm untuk arah y. Kata Kunci: Gedung, ETABS, Pushover, ATC 40 The development of development in the world of education is now increasingly high. This requires the University of Alma Ata Yogyakarta (UAAY) to continue to create and build supporting infrastructure and adequate places for students to be realized in the construction of the AL-Musthofa building. The purpose of this study was to determine the level of structural performance of the Al-Mustofa Yogyakarta building after evaluating the performance of the structure using the Pushover method based on ATC-40 and the value of shear forces and the Al-Mustofa Yogyakarta building after evaluating the performance of the structure using the Pushover method. The calculation results show the Performance Level ATC-40 with a ratio of 0.00591 for the x direction and 0.00535 for the y direction, therefore the performance level of this structure is Immediately Occupancy, which means when an earthquake occurs this building is not damaged. The results of the Pushover analysis using the Etabs program obtained the results of the structural performance (Performance point) with a force of 12729.293 kN, and a maximum displacement of 189.085 mm for the x direction, and 13240.379 kN and a maximum displacement of 171.189 mm for the y direction. Keywords: Building, ETABS, Pushover, ATC 40
| Item Type: | Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir) |
|---|---|
| Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
| Divisions: | Fakultas Sains dan Teknologi > S1 Teknik Sipil |
| Depositing User: | Kaprodi S1 Teknik Sipil UTY |
| Date Deposited: | 17 Jun 2026 07:19 |
| Last Modified: | 17 Jun 2026 07:19 |
| URI: | http://eprints.uty.ac.id/id/eprint/19917 |
Actions (login required)
![]() |
View Item |