EVALUASI KINERJA SEISMIK BANGUNAN GEDUNG DENGAN ANALISIS PUSHOVER EVALUATION OF BUILDING SEISMIC PERFORMANCE USING PUSHOVER ANALYSIS

Maulana, Nurfarhan and kromodiryo, Johan (2023) EVALUASI KINERJA SEISMIK BANGUNAN GEDUNG DENGAN ANALISIS PUSHOVER EVALUATION OF BUILDING SEISMIC PERFORMANCE USING PUSHOVER ANALYSIS. Tugas Akhir thesis, University Of Technology Yogyakarta.

[img] Text
5190811069_Nurfarhan Maulana_Abstrak - DONE.pdf

Download (93kB)

Abstract

Perkembangan pembangunan di dunia pendidikan kini semakin tinggi. Hal ini menuntut Universitas Tidar Magelang (UNTIDAR) untuk terus menciptakan dan membangun prasarana pendukung dan tempat yang memadai bagi mahasiswa dengan di wujudkan dalam pembangunan gedung Laboraturium Terpadu UNTIDAR. Tujuan dari penelitian ini adalah untuk mengetahui level kinerja struktur dari gedung Laboraturium Terpadu UNTIDAR setelah dilakukan evaluasi kinerja struktur dengan metode Pushover berdasarkan ATC-40 dan nilai gaya geser dan gedung Laboraturium Terpadu UNTIDAR setelah dilakukan evaluasi kinerja struktur menggunakan metode Pushover. Metode penelitian ini menggunakan metode Pushover Analysis Nonlinier. Pada penelitian ini menggunakan aplikasi bantuan ETABS 18.1,1. Untuk mewujudkan uraian analisis tersebut, maka langkah analisis yang harus dilakukan sesuai dengan prosedur yang telah ditetapkan. Hasil pehitungan analisis Pushover dengan menggunakan program Etabs maka diperoleh hasil kinerja struktur (Performance point) dengan gaya sebesar 11499,3843 kN, dan Displacement maksimal sebesar 204,418 mm untuk arah x, serta 6443,0535 kN dan Displacement maksimal sebesar 67,324 mm untuk arah y. Berdasarkan tabel Performance Level ATC-40 dengan rasio 0,0102209 untuk arah x dan 0,0033801 untuk arah y maka level kinerja struktur ini adalah Immediately Occupancy, yang berarti saat terjadi gempa maka bangunan gedung ini tidak mengalami kerusakan. Kata kunci: Gedung, ETABS, Pushover, ATC 40 Development developments in the world of education are now increasingly high. This requires Tidar Magelang University (UNTIDAR) to continue to create and build supporting infrastructure and adequate space for students, which is realized in the construction of the UNTIDAR Integrated Laboratory building. The aim of this research is to determine the level of structural performance of the UNTIDAR Integrated Laboratory building after evaluating structural performance using the Pushover method based on ATC-40 and the shear force values of the UNTIDAR Integrated Laboratory building after evaluating structural performance using the Pushover method. This research uses the Nonlinear Pushover Analysis method. This research uses the ETABS 18.1.1 application. To realize the description of the analysis, the analysis steps must be carried out in accordance with established procedures. The results of Pushover analysis calculations using the Etabs program obtained structural performance results (Performance points) with a force of 11499.3843 kN, and a maximum displacement of 204.418 mm in the x direction, and 6443.0535 kN and a maximum displacement of 67.324 mm in the y direction. Based on the ATC-40 Performance Level table with a ratio of 0.0102209 for the x direction and 0.0033801 for the y direction, the performance level of this structure is Immediate Occupancy, which means that when an earthquake occurs, this building is not damaged. Keywords: Building, ETABS, Pushover, ATC 40

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 18 Jun 2026 08:34
Last Modified: 18 Jun 2026 08:34
URI: http://eprints.uty.ac.id/id/eprint/20018

Actions (login required)

View Item View Item