PERBANDINGAN STRUKTUR ATAS BANGUNAN GEDUNG BADAN PENANGGULANGAN BENCANA DAERAH (BPBD) KABUPATEN KLATEN BERDASARKAN SNI 1726 : 2019 DAN SNI 2847 : 2019 COMPARISON OF THE UPPER STRUCTURE OF THE REGIONAL DISASTER MANAGEMENT AGENCY (BPBD) BUILDING OF KLATEN DISTRICT BASED ON SNI 1726: 2019 AND SNI 2847: 2019

Nugroho, David Wahyu and kromodiryo, Johan (2023) PERBANDINGAN STRUKTUR ATAS BANGUNAN GEDUNG BADAN PENANGGULANGAN BENCANA DAERAH (BPBD) KABUPATEN KLATEN BERDASARKAN SNI 1726 : 2019 DAN SNI 2847 : 2019 COMPARISON OF THE UPPER STRUCTURE OF THE REGIONAL DISASTER MANAGEMENT AGENCY (BPBD) BUILDING OF KLATEN DISTRICT BASED ON SNI 1726: 2019 AND SNI 2847: 2019. Tugas Akhir thesis, University Of Technology Yogyakarta.

[img] Text
5190811205_David Wahyu Nugroho_Abstrak - DONE.pdf

Download (102kB)

Abstract

Kabupaten klaten merupakan salah satu kabupaten yang termasuk rawan bencana yaitu ancaman seperti gempa bumi, tsunami, banjir, kekeringan dan tanah longsor. Sebagian besar provinsi rawan bencana di wilayah Indonesia secara hukum telah diwajibkan mendirikan kantor BPBD. Gedung perkantoran merupakan salah satu upaya untuk meningkatkan fasilitas infrastruktur dalam meningkatkan roda perekonomian yang lebih baik. Pekerjaan utama dalam perkantoran adalah kegiatan penanganan informasi yang telah tersedia. Sehingga dalam merencanakan sebuah bangunan Gedung perkantoran ini perlu perencanaan yang baik dan matang ditijau dari segi keamanan, biaya, kegunaan, bentuk, arsitektural, dan struktural. Tujuan dari penelitian ini yaitu meredesain bangunan dan membandingkan desain struktur atas pada kantor BPBD. Metode yang digunakan adalah dengan metode observasi untuk memperoleh data yang berhubungan dengan analisa yang dibahas, metode diskriptif didapatkan dari buku-buku yang mempelajari tentang contoh-contoh analisa yang digunakan dalam perhitungan struktur seperti analisa software ETABS V20. Peraturan yang digunakan dalam menganalisa beban gempa adalah SNI 2847:2019 “Persyaratan Beton Struktural Untuk Bangunan Gedung”. Peraturan yang akan digunakan dalam menganalisis beton bertulang SNI 1726:2019 “Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung Non Gedung”, serta konsep desain yang mengacu pada SNI 1729:2020 tentang Spesfikasi untuk Bangunan Baja Struktural. Hasil perbandingan desain Portal Beton menggunakan SNI 2847 : 2019 dengan SNI 2847 : 2013 didapatkan hasil penulangan sebagai berikut : Terdapat Perubahan Pada balok 1 tulangan tumpuan mengalami peningkatan sejumlah 2. Pada balok 2 tulangan tumpuan dan tulangan lapangan mengalami peningkatan sejumlah 1. Pada balok 3 tulangan tumpuan dan tulangan lapangan tidak mengalami peningkatan. Pada kolom 1 dan 2 mengalami peningkatan sejumlah 2 dan mengalami perubahan pada jarak Sengkang dari 150 mm menjadi 130 mm. Pada tulangan plat lantai ada perubahan pada jarak Sengkang dari 150 mm menjadi 200 mm untuk arah Y, sedangkan untuk arah X tidak mengalami perubahan jarak Sengkang. Pada Perbandingan Rangka Atap baja ini terdapat perubahan pada profil baja IWF, yang sebelumnya berdasarkan SNI 1729 : 2015 menggunakan profil baja kuda - kuda IWF 200.100.5.5.8 dan Gording C 125.50.20.2.3 menggunakan IWF sedangkan berdasarkan SNI 1729 : 2020 menggunakan profil baja kuda – kuda IWF 300.150.6.5.9 dan gording C 150.50.20.2.5. Kata Kunci : Perencanaan, Redesain, Kolom, Balok, Pelat Lantai, Baja Klaten Regency is one of the districts that is prone to disasters, namely threats such as earthquakes, tsunamis, floods, droughts and landslides. Most disaster-prone provinces in Indonesia are legally required to establish BPBD offices. Office buildings are an effort to improve infrastructure facilities to make the economy better. The main job in an office is the activity of handling available information. So, when planning an office building, it is necessary to plan well and carefully review it in terms of safety, cost, usability, shape, architectural and structural aspects. The aim of this research is to redesign the building and compare the design of the upper structure at the BPBD office. The method used is the observation method to obtain data related to the analysis discussed, the descriptive method is obtained from books that study examples of analysis used in structural calculations such as ETABS V20 software analysis. The regulations used in analyzing earthquake loads are SNI 2847:2019 "Structural Concrete Requirements for Buildings". Regulations that will be used in analyzing reinforced concrete SNI 1726:2019 "Procedures for Earthquake Resistance Planning for Non-Building Building Structures", as well as design concepts that refer to SNI 1729:2020 concerning Specifications for Structural Steel Buildings. The results of comparing the concrete portal design using SNI 2847: 2019 with SNI 2847: 2013 showed that the reinforcement results were as follows: There was a change in beam 1, the support reinforcement increased by 2. In beam 2, the support reinforcement and field reinforcement increased by 1. In beam 3, the support reinforcement the support and field reinforcement did not increase. Columns 1 and 2 experienced an increase of 2 and experienced a change in the Sengkang distance from 150 mm to 130 mm. In the floor plate reinforcement there is a change in the Sengkang distance from 150 mm to 200 mm in the Y direction, while in the X direction there is no change in the Sengkang distance. In this comparison of steel roof frames, there are changes to the IWF steel profile, which was previously based on SNI 1729: 2015 using the IWF 200.100.5.5.8 truss steel profile and Gording C 125.50.20.2.3 using IWF while based on SNI 1729: 2020 using the profile steel trusses IWF 300.150.6.5.9 and curtains C 150.50.20.2.5. Keywords: Planning, Redesign, Columns, Beams, Floor Plates, Steel

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 19 Jun 2026 03:59
Last Modified: 19 Jun 2026 03:59
URI: http://eprints.uty.ac.id/id/eprint/20091

Actions (login required)

View Item View Item