PERENCANAAN PONDASI SUBSTATION BUILDING WELLPAD CENTRAL AREA PADA PROYEK PENGEMBANGAN GAS LAPANGAN UNITISASI JAMBARAN-TIUNG BIRU DENGAN MEMPERHITUNGKAN PENGARUH LIKUIFAKSI PLANNING OF THE WELLPAD CENTRAL AREA SUBSTATION BUILDING IN JAMBARAN-TIUNG BIRU UNITIZATION FIELD GAS DEVELOPMENT PROJECT BY CALCULATING THE EFFECT OF LIQUEFACTION

Supriyadi, Adek and Fida Ismaili, Abul (2021) PERENCANAAN PONDASI SUBSTATION BUILDING WELLPAD CENTRAL AREA PADA PROYEK PENGEMBANGAN GAS LAPANGAN UNITISASI JAMBARAN-TIUNG BIRU DENGAN MEMPERHITUNGKAN PENGARUH LIKUIFAKSI PLANNING OF THE WELLPAD CENTRAL AREA SUBSTATION BUILDING IN JAMBARAN-TIUNG BIRU UNITIZATION FIELD GAS DEVELOPMENT PROJECT BY CALCULATING THE EFFECT OF LIQUEFACTION. Tugas Akhir thesis, University Technology Yogyakarta.

[img]
Preview
Text
ABSTRAK_5140811032_Adek Supriyadi Done.pdf

Download (98kB) | Preview

Abstract

ABSTRAK Salah satu dampak yang disebabkan oleh gempa bumi adalah fenomena hilangnya kekuatan lapisan tanah akibat getaran yang disebut dengan likuifaksi. Pada saat terjadi gempa, lapisan tanah yang berpotensi terhadap likuifaksi akan kehilangan kemampuan daya dukungnya, sehingga berpengaruh juga terhadap daya dukung pondasi. Kemungkinan terburuk akibat terjadinya likuifaksi yaitu keruntuhan pada bangunan. Untuk perhitungan potensi likuifaksi dalam penelitian ini menggunakan pendekatan uji lapangan SPT (Standard Penetration Test) dan hasil tes uji laboratorium pada sample tanah di Substation Building Wellpad Central Area. Setelah itu dilakukan perencanaan pondasi dangkal dan pondasi tiang pancang untuk Substation Building. Pondasi dangkal yang diperhitungkan adalah tipe Rectangular Footing. Dan untuk pondasi tiang, Pile Properties yang direncanakan adalah Cylinder Precast Pre-stressed Concrete Pile (PC Pile) atau yang sering disebut juga Spun Pile dengan diameter 350mm kelas A3 produk PT. WIKA BETON. Dari hasil perhitungan yang telah dilakukan, didapat potensi likuifaksi pada kedalaman 1,85-4,65m. Namun hasil perhitungan tersebut perlu dibandingkan dengan pendekatan uji lapangan lainnya seperti Cone Penetration Test (CPT), Becker Penetration Test (BPT), maupun Vane Shear Test (VS). Pada perencanaan Pondasi dangkal, didapat Kapasitas Dukung ijin dengan metode Meyerhof (1955)=110,52 kN dImana dimensi rencana pondasi=1m x 1m x 0,3m. Kemudian pada perencanaan pondasi tiang, direncanakan panjang tiang=13 m, lalu didapat Kapasitas Dukung ijin Qall=550 kN. Konfigurasi tiang=2 dengan efisiensi tiang kelompok= 0,76 dan Kapasitas Dukung Tiang Kelompok=1302,07 kN. Dalam perhitungan Tiang mendukung beban lateral, diambil nilai terkecil Antara perhitungan berdasarkan defleksi toleransi atau berdasarkan keruntuhan tanah/tiang, didapat Gaya lateral ijin= 14,04 kN. Untuk perhitungan penurunan tiang tunggal dan kelompok, penulis menggunakan program bantu Allpile v7.3b dan didapat nilai penurunan tiang tunggal= 0,326 cm serta penurunan tiang kelompok= 0,245 cm. Kata kunci : Gempa; Likuifaksi; Pondasi dangkal; Pondasi Tiang; Allpile v7.3b ABSTRACT One of the impacts caused by an earthquake is the phenomenon of the loss of soil strength due to vibrations known as liquefaction. When an earthquake occurs, the soil layer that has the potential for liquefaction will lose its bearing capacity, so it also affects the bearing capacity of the foundation. The worst possible result of liquefaction is a collapse in the building. For the calculation of the potential for liquefaction in this study using the SPT (Standard Penetration Test) field test approach and laboratory test results on soil samples at the Well pad Central Area Substation Building. After that, the planning of shallow foundations and pile foundations is carried out for the Substation Building. The shallow foundation that is taken into account is the Rectangular Footing type. And for the pile foundation, the planned Pile Properties is a Cylinder Precast Pre-Stressed Concrete Pile (PC Pile) or what is often called a Spun Pile with a diameter of 350mm, class A3, the product of PT. WIKA BETON. From the results of calculations that have been done, the potential for liquefaction is obtained at a depth of 1.85-4.65m. However, the results of these calculations need to be compared with other field test approaches such as the Cone Penetration Test (CPT), the Becker Penetration Test (BPT), and the Vane Shear Test (VS). In the shallow foundation planning, it is obtained that the carrying capacity of the permit with the Meyerhof method (1955) = 110.52 kN where the dimensions of the foundation plan = 1m x 1m x 0.3m. Then in the pile foundation planning, the length of the pile is planned = 13 m, then we get the support capacity for Qall permission = 550 kN. Pile configuration = 2 with group pile efficiency = 0.76 and group pole bearing capacity = 1302.07 kN. In the calculation of the pile supporting the lateral load, the smallest value between the calculation is based on the deflection tolerance or based on the collapse of the soil / pile, obtained the allowable lateral force = 14.04 kN. For the calculation of the settlement of single pile and group pile, the writer used the auxiliary program Allpile v7.3b and the value of single pile settlement = 0.326 cm and the drop in group pile = 0.245 cm. Key words: Earthquake; Liquefaction Shallow foundation; Pillar Foundation; Allpile v7.3b DAFTAR PUSTAKA Hardiyatmo, H.C. (2010). Teknik Pondasi 1. Gadjah Mada University Press. Yogyakarta. Hardiyatmo, H.C. (2010). Teknik Pondasi 2. Gadjah Mada University Press. Yogyakarta. Ikhsan. (2011). Analisis Potensi Likuifaksi Dari Data CPT dan SPT dengan Studi Kasus PLTU ENDE Nusa Tenggara Timur. Universitas Indonesia. Ariandi, Manoppo dan Sumarpouw. (2019). Kajian Potensi Likuifaksi Pada Sekitar Pondasi Jembatan Prategang Di Sawangan. Universitas Sam Ratulangi. Mina, Indera dan Sudirman. (2018). Analisa Potensi Likuifaksi Berdasarkan Data SPT Studi Kasus Proyek Pembangunan Gedung Baru UNTIRTA (Sindang Sari). Universitas Sultan Ageng Tirtayasa. Husnah. (2018). Analisis Kapasitas Daya Dukung Pondasi Tiang Pancang Pada Proyek Pembangunan Pondasi Tissue Block 5 & 6. Universitas Lancang Kuning. Syafei. (2016). Perencanaan Pondasi Tiang Pancang dengan Memperhitungkan Pengaruh Likuifaksi Pada Proyek Pembangunan Hotel di Lombok. Intitut Teknologi Sepuluh November. Badan Standarisasi Nasional. (2012). Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung(03-1726).Jakarta. https://www.maps.google.co.id https://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 30 Dec 2021 08:31
Last Modified: 30 Dec 2021 08:31
URI: http://eprints.uty.ac.id/id/eprint/6779

Actions (login required)

View Item View Item