EVALUASI SISTEM PROTEKSI KEBAKARAN PADA BANGUNAN HOTEL ZODIAK BANDUNG EVALUATION OF FIRE PROTECTION SYSTEM IN BANDUNG ZODIAK HOTEL BUILDING

Faturrahman, Dwika and Kurniati, Dwi (2021) EVALUASI SISTEM PROTEKSI KEBAKARAN PADA BANGUNAN HOTEL ZODIAK BANDUNG EVALUATION OF FIRE PROTECTION SYSTEM IN BANDUNG ZODIAK HOTEL BUILDING. Tugas Akhir thesis, University Technology Yogyakarta.

[img] Text
5140811120_Dwika Faturrahman.pdf

Download (30kB)

Abstract

Pembangunan di kota Bandung semakin meningkat. Pembangunan gedung yang beragam dan kompleks menuntut aspek keselamatan dan rasa aman terhadap bangunan gedung dan lingkungannya. Salah satu aspek keselamatan yang penting dari sebuah bangunan gedung adalah keselamatan dari bahaya bencana kebakaran. Tujuan penelitian ini adalaha untuk mengetahui tingkat keandalan bangunan Hotel Zodiak Bandung terhadap bahaya kebakaran dengan mencari Nilai Keandalan Sistem Keselamatan Bangunan pada Hotel Zodiak Bandung.Metode yang digunakan dalam penelitian ini dengan melakukan metode observasi deskriptif. Proses observasi dan penilaian terhadap empat parameter keandalan sistem pengamanan gedung dengan melakukan cheklist atau penilaian langsung terhadap sistem proteksi kebakaran bangunan gedung di lapangan pada bangunan Hotel Zodiak Bandung, yaitu kelengkapan tapak, alat penyelamat, prroteksi aktif, dan proteksi pasif dengan mengacu pada Peraturan Pekerjaan Umum Nomor 26/RRT/M/2008 tentang Persyaratan Teknis Sistem Proteksi Kebakaran pada Bangunan dan Lingkungan Bangunan dan Keselamatan Buku Inspeksi Bangunan (Pd-T-11-2005-C) dari Badan Litbang Kementrian Pekerjaan Umum dan beberapa Standar Basional Indonesia terkait untuk mengetahui nilai keandalan sistem keselamatan banguunan terhadap bahaya kebakaran deengan objek penelitian di Hotel Zodiak Bandung dan untuk mencari Nilai Keandalan Sistem Keselamatan Bangunan (NKSKB).Hasil dari penelitian ini menghasilkan Nilai Keandalanan Sistem Keselamatan Bangunan (NKSKB) dengan nilai 86,47% dengan hasil nilai sarana penyelamatan 23,8; sarana proteksi pasif 23,15; kelengkapan tapak 21,07; dan sarana proteksi aktif 18,47. Menurut hasil Nilai Keandalan Sistem Keselamatan yang didapatkan dapat disimpulkan bahwa gedung Hotel Zodiak Bandung sudah sangat baik dan memenuhi syarat dalam persiapan proteksi kebakaran pada bangunan gedung. Kata kunci: Bandung, Evaluasi, Keandalan, Kebakaran, Proteksi Development in the city of Bandung is increasing. The construction of various and complex buildings demands safety and security aspects for buildings and their environment. One of the important safety aspects of a building is safety from fire hazards. The purpose of this study was to determine the level of reliability of the Zodiak Bandung Hotel building against fire hazards by looking for the Reliability Value of the Building Safety System at the Zodiak Hotel Bandung. The method used in this research is descriptive observation method. The process of observing and assessing the four parameters of the reliability of the building security system by conducting a checklist or direct assessment of the building fire protection system in the field at the Zodiak Bandung Hotel building, namely site completeness, rescue equipment, active protection, and passive protection with reference to Public Works Regulation No. 26/RRT/M/2008 concerning Technical Requirements for Fire Protection Systems in Buildings and the Building Environment and Safety of Building Inspection Books (Pd-T-11-2005-C) from the Research and Development Agency of the Ministry of Public Works and several related Indonesian National Standards to determine the reliability value building safety system against fire hazards with the object of research at Hotel Zodiak Bandung and to find the Value of Building Safety System Reliability (NKSKB). The results of this study are the Building Safety System Reliability Value (NKSKB) with a value of 86.47% with the result of a rescue facility value of 23.8; passive means of protection 23.15; site completeness 21.07; and means of active protection 18.47. According to the results of the Safety System Reliability Value obtained, it can be concluded that the Zodiak Bandung Hotel building is very good and meets the requirements in the preparation of fire protection in buildings. Keywords: Bandung, Evaluation, Reliability, Fire, Protection

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 24 Mar 2022 02:34
Last Modified: 24 Mar 2022 02:34
URI: http://eprints.uty.ac.id/id/eprint/9340

Actions (login required)

View Item View Item