Analisis Keandalan Penyulang Sistem Distribusi 20KV di PT. PLN (Persero) APJ Klaten Rayon Boyolali

Wijayanti, NIken and Alfi, Ikrima (2018) Analisis Keandalan Penyulang Sistem Distribusi 20KV di PT. PLN (Persero) APJ Klaten Rayon Boyolali. Tugas Akhir thesis, University of Technology Yogyakarta.

[img]
Preview
Text
Naskah Publikasi_Niken Wijayanti_5140711034.pdf

Download (755kB) | Preview

Abstract

ABSTRAK Kualitas energi listrik yang diterima pelanggan dipengaruhi oleh sistem pendistribusiannya, diperlukan sistem distribusi tenaga listrik dengan keandalan yang baik. Suatu sistem distribusi tenaga listrik dapat dikatakan andal apabila gangguan dan pemadaman yang terjadi dalam periode waktu tertentu dibawah angka indeks keandalan yang ditetapkan. Ukuran keandalan suatu sistem dapat dinyatakan dengan menghitung SAIDI (System Average Interruption Duration Index) dan SAIFI (System Average Interruption Frequency Index) yaitu seberapa sering sistem mengalami pemadaman dan berapa lama pemadaman terjadi dalam rentang waktu tertentu yakni satu tahun. Penelitian ini bertujuan untuk menganalisa keandalan sistem distribusi tenaga listrik di PT. PLN (Persero) UPJ Klaten Rayon Boyolali berdasarkan indeks keandalan SAIDI dan SAIFI dengan menggunakan data gangguan distribusi yang terjadi selama tahun 2017. Adapun langkah yang dilakukan oleh penulis yaitu dengan mengumpulkan gangguan, data pemadaman, dan data pelanggan yang diperoleh di PT. PLN (Persero) UPJ Klaten. Hasil yang diperoleh bahwa menurut IEEE std 1366 – 2003, Penyulang MJO-9 yang dikategorikan tidak andal karena nilai SAIDI melebihi batas yang ditentukan IEEE yakni 7,779 jam/pelanggan/tahun. Menurut WCS (World Class Service) dan WCC (World Class Company), Penyulang MJO-7 dan MJO-9 yang dikategorikan tidak andal karena nilai SAIDI melebihi batas yang ditentukan WCS dan WCC yakni 1,859 dan 7,779 jam/pelanggan/tahun. Sedangkan gangguan tertinggi disebabkan oleh binatang dan ada beberapa potensi perbaikan baik secara teknis dan non-teknis. Kata kunci: distribusi, keandalan, SAIDI, SAIFI ABSTRAK The quality of electrical energy that received by costumers is influenced by the distribution system. That is required power distribution system with good reliability. A power distribution system can be said reliably if interference and blackouts that occur wihin a certain period of time under the setablished reliability index. The size of the reliability of a system can be expressed by calculating SAIDI (System Average Interruption Duration Index) and SAIFI (System Average Interruption Frequency Index) that is how often the system experienced blackouts and how long the blackout occurs within a certain timeframe of one year. This study aims to analyze the reliability of power distribution system in PT. PLN Rayon Boyolali based on SAIDI and SAIFI reliability index using distribution distrubances data that occured during 2017. The steps undertaken by the author is to collect data distrubance, blackout data, and costumer data obtained at PT. PLN Rayon Boyolali. The results obtained that according to IEEE std 1366 – 2003, the MJO-9 feederis categorized less reliably as the SAIDI value exceeds the IEEE defined limit of 7,779 hours/costumer/year. Obtained that according to WCS and WCC, the MJO-7 and MJO-9 feeder is categorized less reliably as the SAIDI value exceeds the WCS and WCC defined limit of 1,859 and 7,779 hours/costumer/year. While for the highest disorder caused by animals and there are some potential for technical and non technical breed reliability improvement. Kata kunci: distribution, reliability, SAIDI, SAIFI

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Sains Dan Teknologi > S1 Teknik Elektro
Depositing User: Kaprodi Teknik Elektro
Date Deposited: 19 Nov 2018 02:49
Last Modified: 19 Nov 2018 02:49
URI: http://eprints.uty.ac.id/id/eprint/2368

Actions (login required)