EVALUASI KINERJA STRUKTUR GEDUNG PELAYANAN RSUD TIDAR KOTA MAGELANG METODE PUSHOVER ANALYSIS EVALUATION OF STRUCTURAL PERFORMANCE OF TIDAR REGIONAL GENERAL HOSPITAL SERVICE BUILDING , MAGELANG USING PUSHOVER METHOD

Bukhori, Ridwan and Budianto, Johan (2020) EVALUASI KINERJA STRUKTUR GEDUNG PELAYANAN RSUD TIDAR KOTA MAGELANG METODE PUSHOVER ANALYSIS EVALUATION OF STRUCTURAL PERFORMANCE OF TIDAR REGIONAL GENERAL HOSPITAL SERVICE BUILDING , MAGELANG USING PUSHOVER METHOD. Tugas Akhir thesis, University Technology Yogyakarta.

[img]
Preview
Text
5150811396_Ridwan Bukhori.pdf

Download (160kB) | Preview

Abstract

ABSTRAK Menurut USGS (United States Geological Survey) Asia Tenggara adalah salah satu daerah yang dilewati ring of fire (Cincin Api Pasifik) yang rentan dan sering terjadinya gempa. Sehingga wilayah Indonesia yang terletak di Asia Tenggara pun akan berdampak gempa yang nantinya akan mempengaruhi bangunan yang ada di Indonesia. Maka dari itu faktor beban gempa pada bangunan di Indonesia harus diperhitungkan untuk menjaga keselamatan penghuni yang ada di dalamnya. Pada penelitian ini gedung yang akan dievaluasi dengan metode pushover adalah RSUD (Rumah Sakit Umum Daerah) Tidar, Kota Magelang yang terdiri dari 1 basement, 1 lantai dasar dan 7 lantai menggunakan struktur beton bertulang. Adapun peraturan yang digunakan diantaranya SNI 1727:2012, 1727:2013, Peta Gempa 2017, dan FEMA 356. Adapun software yang digunakan untuk menganalisa adalah SAP 2000 versi 20. Dari hasil pembahasan yang dilakukan didapatkan nilai untuk PUSHx Target Perpindahan, δT = 0,268 m dan batasan simpangan = 0,59 % yang dimana struktur masih dalam keadaan Immediate Ocupancy. Dan nilai untuk PUSHy Target Perpindahan, δT = 0,287 m dan batasan simpangan = 0,63% yang dimana struktur juga masih dalam keadaan Immediate Ocupancy yang berarti tidak ada kerusakan yang berarti pada struktur, dimana kekuatan dan kekakuannya kira-kira hampir sama dengan kondisi sebelum gempa Adapun skema keruntuhan sendi plastis sesuai dengan konsep Strong Column and Weak Beam. Kata Kunci : Rumah Sakit, Pushover, FEMA 356 ABSTRACT According to the USGS (United States Geological Survey) Southeast Asia is one of the areas that is crossed by the Pacific Ring of Fire which is vulnerable and frequent earthquakes. So that the territory of Indonesia which is located in Southeast Asia will also have an earthquake impact which will affect buildings in Indonesia.Therefore, the earthquake load factor in buildings in Indonesia must be taken into account to maintain the safety of the occupants in it. In this study the building that will be evaluated by the pushover method is the Tidar Regional General Hospital Service Building, Magelang City which consists of 1 basement, 1 ground floor and 7 floors using reinforced concrete structures. The regulations used include SNI 1727: 2012, 1727: 2013, Earthquake Map 2017, and FEMA 356. The software used to analyze is SAP 2000 version 20. From the results of the discussion conducted obtained values for the PUSHx Displacement Target, δT = 0.268 m and the deviation limit = 0.59% where the structure is still in an Immediate Ocupancy state. The value for the PUSHy Transfer Target, δT = 0.287 m and the deviation limit = 0.63% where the structure is also still in an Immediate Ocupancy condition which means there is no significant damage to the structure, where the strength and stiffness are approximately similar to the conditions before the earthquake The plastic joint collapse scheme is in accordance with the concept of Strong Column and Weak Beam. Keywords: Hospital, Pushover, FEMA 356

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 16 Oct 2020 07:00
Last Modified: 16 Oct 2020 07:00
URI: http://eprints.uty.ac.id/id/eprint/5905

Actions (login required)

View Item View Item