EVALUASI KINERJA STRUKTUR GEDUNG DENGAN METODE PUSHOVER ANALYSIS SESUAI PEDOMAN ATC-40 (Studi Kasus: SMP 3 Muhammadiyah Yogyakarta) PERFORMANCE EVALUATION OF BUILDING STRUCTURE USING PUSHOVER ANALYSIS METHOD ACCORDING TO ATC-40 GUIDELINE (Case Study: SMP 3 Muhammadiyah Yogyakarta)

Dewi, Dianita Ika Roshinta and Masagala, Algazt Aryad (2020) EVALUASI KINERJA STRUKTUR GEDUNG DENGAN METODE PUSHOVER ANALYSIS SESUAI PEDOMAN ATC-40 (Studi Kasus: SMP 3 Muhammadiyah Yogyakarta) PERFORMANCE EVALUATION OF BUILDING STRUCTURE USING PUSHOVER ANALYSIS METHOD ACCORDING TO ATC-40 GUIDELINE (Case Study: SMP 3 Muhammadiyah Yogyakarta). Tugas Akhir thesis, University Technology Yogyakarta.

[img]
Preview
Text
5170821002_Dianita Ika Roshinta Dewi.pdf

Download (137kB) | Preview

Abstract

ABSTRAK Pembangunan gedung SMP 3 Muhammadiyah Yogyakarta merupakan kegiatan yang bertujuan untuk meningkatkan mutu pada proses belajar mengajar. Pada proses pembangunan gedung terjadi permasalahan internal yang mengakibatkan proses pengerjaan berhenti sementara dan terjadi pergantian kontraktor. Ketika pembangunan kembali dilaksanakan, proses assesment pada gedung diperlukan untuk mengetahui mutu gedung yang sudah terbangun. Pada pengerjaan proses assesment tersebut terdapat kesalahan prosedur yang mengakibatkan struktur dari bangunan mengalami kerusakan. Beberapa tulangan utama yang menjadi bagian utama dari struktur kolom terputus saat proses core drill. Melihat permasalah tersebut perlu adanya pemeriksaan terdahap evaluasi kinerja struktur. Metode yang digunakan dalam pemeriksaan evaluasi kinerja struktur adalah pushover analysis yang disesuaikan dengan pedoman ATC-40. Output dari pushover analysis ini adalah level kerusakan bangunan setelah diberikan gaya dorong tertentu. ATC-40 merupakan salah satu pedoman yang digunakan dalam penentuan level kerusakan. Level kerusakan yang dihasilkan dapat digunakan sebagai evaluasi keamanan struktur setelah terjadi gempa. Berdasarkan pushover analysis yang telah dilakukan terhadap gedung SMP 3 Muhammadiyah Yogyakarta didapatkan nilai performance point sebesar Sa= 0,091 dan Sd= 0,017 untuk push x sedangkan untuk nilai dari push y adalah Sa= 0,089 dan Sd= 0,016. Sedangkan untuk nilai maksimum total drift 0,00113 dan nilai maksimum inelastic drif 0,00095 pada push x dan nilai maksimum total drift 0,00128 dan nilai maksimum inelastic drif 0,001036 pada push y. berdasarkan hasil tersebut didapatkan level kerusakan struktur adalah Immediiate Occupancy (IO) yang artinya apabila terjadi gempa, hanya sedikit kerusakan struktural yang terjadi. Karakteristik dan kapasitas sistem penahan gaya vertikal dan lateral pada struktur masih masih sama dengan kondisi dimana gempa belum terjadi, sehingga bangunan aman dan dapat langsung dipakai. Kata kunci: Evaluasi Kinerja Struktur, Pushover Analysis, ATC-40 ABSTRACT The construction of Yogyakarta Muhammadiyah 3 Junior High School building is an activity that aims to improve the quality of the teaching and learning process. In the process of building construction internal problems occur which result in the process of temporarily stopping work and contractor changes. When rebuilding is carried out, the assessment process on the building is needed to determine the quality of the building that has been built. In working on the assessment process there are procedural errors that result in the structure of the building being damaged. Some of the main bars that are the main part of the column structure are broken during the core drill process. Seeing these problems there needs to be an examination of the structural performance evaluation. The method used in the structural performance evaluation check is pushover analysis which is adjusted to the ATC-40 guidelines. The output of this pushover analysis is the level of damage to the building after being given a certain thrust. ATC-40 is one of the guidelines used in determining the level of damage. The level of damage produced can be used as an evaluation of the safety of structures after an earthquake. Based on the pushover analysis that has been done on the Muhammadiyah 3 Yogyakarta Junior High School building, the performance point value is Sa = 0.091 and Sd = 0.017 for push x while the value of push y is Sa = 0.089 and Sd = 0.016. As for the maximum total drift value of 0.00113 and the maximum value of inelastic drif 0,00095 on push x and the maximum total value of drift 0.00128 and the maximum value of inelastic drif 0.001036 on push y. Based on these results the level of structural damage is Immediate Occupancy (IO) which means that if an earthquake occurs, only a small amount of structural damage occurs. The characteristics and capacity of the vertical and lateral force retaining system on the structure are still the same as the conditions where the earthquake has not occurred, so that the building is safe and can be used immediately. Keywords: Structure Performance Evaluation, Pushover Analysis, ATC-40

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 16 Oct 2020 07:10
Last Modified: 16 Oct 2020 07:10
URI: http://eprints.uty.ac.id/id/eprint/5910

Actions (login required)

View Item View Item