PERANCANGAN ULANG GEDUNG KAMPUS FAKULTAS TEKNIK UNIVERSITAS PGRI YOGYAKARTA DENGAN MENGGUNAKAN METODE FLAT SLAB DAN DROP PANEL REDESIGN OF CAMPUS BUILDING OF FACULTY OF ENGINEERING, YOGYAKARTA PGRI UNIVERSITY USING FLAT SLAB METHODS AND DROP PANEL

Gaina, Adelbertus Umbu Loli and Kurniati, Dwi (2020) PERANCANGAN ULANG GEDUNG KAMPUS FAKULTAS TEKNIK UNIVERSITAS PGRI YOGYAKARTA DENGAN MENGGUNAKAN METODE FLAT SLAB DAN DROP PANEL REDESIGN OF CAMPUS BUILDING OF FACULTY OF ENGINEERING, YOGYAKARTA PGRI UNIVERSITY USING FLAT SLAB METHODS AND DROP PANEL. Tugas Akhir thesis, University Technology Yogyakarta.

[img]
Preview
Text
5160811079_ADELBERTUS UMBU LG.pdf

Download (302kB) | Preview

Abstract

ABSTRAK Metode Flat slab merupakan pelaksanaan konstruksi pelat beton bertulang tanpa balok dengan keunggulan yang dimiliki antara lain dapat mengurangi ketinggian per lantai serta mengurangi beban struktur itu sendiri. Tujuan dari penelitian ini adalah untuk mengetahui dimensi dan penulangan Pelat, Drop Panel serta kolom dari Gedung Kampus Fakultas Teknik Universitas PGRI Yogyakarta. Metode yang digunakan dalam Tugas akhir ini sesuai dengan peraturan yang berlaku yaitu SNI 1727-2013 dan SNI 03-1727-1989 untuk pembebanan; SNI 1726:2012, SNI 1726:2019 dan Peta Sumber dan bahaya Gempa Indonesia Tahun 2017 untuk beban gempa; SNI 2847-2013 untuk perencanaan pelat, drop panel dan kolom dengan bantuan software Etabs 2016. Berdasarkan analisis dan perhitungan yang telah dilakukan diperoleh tebal pelat lantai 265 mm dengan tulangan D22-150 mm untuk lajur kolom dan D22-250 mm untuk lajur tengah untuk pelat pada arah memanjang dan tulangan D19-250 mm untuk pelat dengan arah melebar pada lajur kolom dan lajut tengah. Tebal pelat atap 165 mm dengan tulangan D16-250 mm untuk lajur kolom dan lajur tengah untuk pelat pada arah memanjang dan tulangan D12-250 mm untuk pelat dengan arah melebar pada lajur kolom dan lajut tengah. Tebal drop panel untuk pelat lantai 250 mm, tebal drop panel untuk pelat atap 150 mm dengan lebar drop panel dalam 15 tipe beragam menyesuaikan ukuran penampang pelat dengan tulangan D13-130 mm untuk arah x maupun arah y. Menggunakan 3 jenis kolom yaitu kolom 1 (1000 x 1000mm) 20D25, kolom 2 (700 x 700 mm) 16D22, dan kolom 3 (300 x 300mm) 8D12. Hasil akhir juga diketahui bahwa perencanaan ulang struktur dengan metode flat slab dan drop panel lebih mahal 18,52% dari struktur pelat dan balok (konvensional) pada segi biaya. Sedangkan untuk volume beton struktur flat slab-drop panel lebih mahal hingga 61,46% dari sturktur pelat-balok (konvensional) sehingga secara keseluruhan, struktur flat slab-drop panel lebih mahal. Kata kunci: Drop Panel, Flat slab, Konvensional, Mengurangi, Redesign Abstract The flat slab method is the implementation of reinforced concrete slab construction without blocks with the advantages of reducing the height per floor and reducing the load on the structure itself. The purpose of this study was to determine the dimensions and reinforcement of plates, drop panels and columns of the Campus Building, Faculty of Engineering, University of PGRI Yogyakarta. The method used in this final project was in accordance with the applicable regulations, namely SNI 1727-2013 and SNI 03-1727-1989 for loading; SNI 1726: 2012, SNI 1726: 2019 and Map of the Source and the Dangers of the Indonesian Earthquake 2017 for earthquake loads; SNI 2847-2013 for plate, drop panel and column planning with the help of 2016 Etabs software. Based on the analysis and calculations that have been carried out, it was obtained that the floor slab thickness was 265 mm with D22-150 mm reinforcement for column and D22-250 mm for the middle row for the plate in the longitudinal direction and reinforcement D19-250 mm for the plate with the width direction of the column and knit the middle. The thickness of the roof plate was 165 mm with D16-250 mm reinforcement for column and middle row for plates in the longitudinal direction and reinforcement D12-250 mm for plates in the widening direction in column and middle row. Drop panel thickness for floor plate was 250 mm, drop panel thickness for roof plate was 150 mm with drop panel width in 15 different types according to the size of the cross section of the plate with reinforcement D13-130 mm for both x and y directions. It used 3 types of columns, namely column 1 (1000 x 1000mm) 20D25, column 2 (700 x 700 mm) 16D22, and column 3 (300 x 300mm) 8D12. The final result mentioned that the re-planning of the structure using the flat slab and drop panel method was 18.52% more expensive than the conventional plate and beam structure in terms of cost. Whereas for the concrete volume of flat slab-drop panel structures, it was more expensive up to 61.46% of the (conventional) plate-beam structure so that overall flat slab-drop panel structures were more expensive. Keywords: Drop Panel, Flat slab, Conventional, Reduce, Redesign

Item Type: Thesis (Skripsi, Tugas Akhir or Kerja Praktek) (Tugas Akhir)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Sains dan Teknologi > S1 Teknik Sipil
Depositing User: Kaprodi S1 Teknik Sipil UTY
Date Deposited: 21 Oct 2020 09:57
Last Modified: 21 Oct 2020 09:57
URI: http://eprints.uty.ac.id/id/eprint/5974

Actions (login required)

View Item View Item